Signed in as:
filler@godaddy.com
Anka Lithium Battery Powered Smoke Alarms are cost effective and simple to set up and install. It is perfectly legal for a homeowner to self-install battery powered alarms. You cannot however self-install Hardwired Alarms. You will require the services of a licensed electrician.
Before installing, please read this guide, including how to pair your alarms to each other and where and where not to install.
HOW TO PAIR YOUR ALARMS
Remove your new Anka Smoke Alarms from the packaging and place in a row on a table.
HINT
The master alarm will flash red rapidly for just one minute waiting for your other alarms to be paired. If after 1 minute you have not paired all alarms, then simply go back to POINT 3 above and continue the pairing process. Any alarm paired in the first one minute will remain paired, no need to do these alarms again.
TROUBLESHOOTING
Alarm fails to pair (does not activate when tested) do the following.
Press and hold the centre button on the failed alarm until you count FOUR GREEN LIGHTS then release. After you release, the alarm will flash red twice confirming that the alarm is cleared of data and has been returned to factory status. Now refer from POINT 3 above and retry to pair the alarm.
Remote fails to pair.
Press and hold the test button on the remote until you count FOUR RED LIGHTS then release. After you release, the alarm will flash red twice confirming that the remote is cleared of data and has been returned to factory status. Now refer from POINT 3 above and retry to pair the remote.
WHERE TO INSTALL YOUR ALARMS
Where practicable smoke alarms must be placed on the ceiling. Smoke alarms must not be placed:
i) within 300mm of a corner of a ceiling and a wall
ii) within 300mm of a light fitting
iii) within 400mm of an air-conditioning vent
iv) within 400mm of the blades of a ceiling fan.
There are special requirements for stairways, sloping ceilings, and ceilings with exposed beams. These requirements are explained in the Building Fire Safety Regulation 2008. Penalties may be imposed for non-compliance with the law.
Recent changes in legislation have made it necessary for home owners in Queensland to have an interconnected smoke alarm system installed prior settlement. Landlords are also obliged to upgrade to an interconnected system.
Watch this video demonstrating how to interconnect and test the AJ series Alarm
Copyright © 2023 ANKA-SECURITY.COM.AU - All Rights Reserved.